Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Infection and Chemotherapy ; : 611-615, 2020.
Article in English | WPRIM | ID: wpr-898601

ABSTRACT

The ichroma Chikungunya virus (CHIKV) IgG/IgM (Boditech Med Inc., Chuncheon, Korea) is a newly developed rapid lateral flow immunoassay for detection of anti- CHIKV-IgG/ IgM. This study conducted with thirty-six anti-CHIKV IgG positive sera, 57 anti-CHIKV IgM positive sera and 163 anti-CHIKV IgG/IgM negative sera which were confirmed by commercial enzyme-linked immunosorbent assays (ELISAs) (Inbios CHIKjj Detect™ IgM Capture ELISA, Inbios CHIKjj Detect™ IgG ELISA (InBios International Inc., Seattle, WA, USA), Anti-CHIKV ELISA (IgM), Anti- CHIKV ELISA (IgG) (Euroimmun, Lübeck, Germany)). The ichroma detected all 36 anti-CHIKV IgG and 57 anti-CHIKV IgM positivity (100% sensitivity). For 163 anti-CHIKV IgG/IgM negative sera, the ichroma showed one false positive for IgM (99.4% specificity). The ichroma showed no cross-reactivity and no interference. The ichroma demonstrated good diagnostic performance compared to the current ELISAs.

2.
Infection and Chemotherapy ; : 611-615, 2020.
Article in English | WPRIM | ID: wpr-890897

ABSTRACT

The ichroma Chikungunya virus (CHIKV) IgG/IgM (Boditech Med Inc., Chuncheon, Korea) is a newly developed rapid lateral flow immunoassay for detection of anti- CHIKV-IgG/ IgM. This study conducted with thirty-six anti-CHIKV IgG positive sera, 57 anti-CHIKV IgM positive sera and 163 anti-CHIKV IgG/IgM negative sera which were confirmed by commercial enzyme-linked immunosorbent assays (ELISAs) (Inbios CHIKjj Detect™ IgM Capture ELISA, Inbios CHIKjj Detect™ IgG ELISA (InBios International Inc., Seattle, WA, USA), Anti-CHIKV ELISA (IgM), Anti- CHIKV ELISA (IgG) (Euroimmun, Lübeck, Germany)). The ichroma detected all 36 anti-CHIKV IgG and 57 anti-CHIKV IgM positivity (100% sensitivity). For 163 anti-CHIKV IgG/IgM negative sera, the ichroma showed one false positive for IgM (99.4% specificity). The ichroma showed no cross-reactivity and no interference. The ichroma demonstrated good diagnostic performance compared to the current ELISAs.

3.
Annals of Laboratory Medicine ; : 86-90, 2019.
Article in English | WPRIM | ID: wpr-719474

ABSTRACT

The detection and quantification of hepatitis B virus (HBV) DNA plays an important role in diagnosing and monitoring HBV infection as well as in assessing the therapeutic response. We compared the analytical performance of a random access, fully automated HBV assay—DxN VERIS Molecular Diagnostics System (Beckman Coulter, Brea, CA, USA)—with that of Abbott RealTime HBV assay (Abbott Laboratories, Des Plaines, IL, USA). The between-day precision of the VERIS assay ranged from 0.92% (mean 4.68 log IU/mL) to 4.15% (mean 2.09 log IU/mL) for pooled sera from HBV patients. HBV DNA levels measured by the VERIS HBV assay correlated with the calculated HBV DNA levels (r²=0.9994; P < 0.0001). The lower limit of quantification was estimated as 8.76 IU/mL (Probit analysis, 95% confidence interval: 7.32–12.00 IU/mL). Passing-Bablok regression analysis showed good concordance between the VERIS and RealTime assays for 187 chronic HBV samples (y=−0.2397+0.9712x; r=0.981), as well as for 20 drug-resistant HBV genotype C positive samples (y=−0.5415+0.9954x; r=0.961). The VERIS assay demonstrated performance similar to the RealTime assay and is suitable for high-throughput HBV DNA monitoring in large hospital laboratories.


Subject(s)
Humans , DNA , Genotype , Hepatitis B virus , Hepatitis B , Hepatitis , Laboratories, Hospital , Pathology, Molecular
4.
Annals of Laboratory Medicine ; : 566-571, 2019.
Article in English | WPRIM | ID: wpr-762437

ABSTRACT

ELISAs and rapid diagnostic tests (RDTs) are widely used for diagnosing dengue virus (DENV) infection. Using 138 single blood samples, we compared the ability to detect non-structural (NS)-1 antigen and anti-DENV IgM/IgG antibodies among (1) DENV Detect NS1 ELISA, DENV Detect IgM capture ELISA and DENV Detect IgG ELISA (InBios International, Inc.); (2) Anti-Dengue virus IgM Human ELISA and Anti-Dengue virus IgG Human ELISA (Abcam); (3) Dengue virus NS1 ELISA, Anti-Dengue virus ELISA (IgM) and Anti-Dengue virus ELISA (IgG) (Euroimmun); (4) Asan Easy Test Dengue NS1 Ag 100 and Asan Easy Test Dengue IgG/IgM (Asan Pharm); (5) SD BIOLINE Dengue Duo (Standard Diagnostics); and (6) Ichroma Dengue NS1 and Ichroma Dengue IgG/IgM (Boditech Med). For NS1 antigen detection, InBios and Euroimmun showed higher sensitivities (100%) than the RDTs (42.9–64.3%). All tests demonstrated variable sensitivities for IgM (38.1–90.5%) and IgG (65.7–100.0%). InBios and Boditech Med demonstrated higher sensitivity (95.6% and 88.2%, respectively) than the other tests for combined NS1 antigen and IgM antibody. Five NS1 antigen tests had good agreement (92.8–98.6%) without showing positivity for chikungunya. However, all IgG tests demonstrated potential false-positivity with variable ranges. Clinical laboratories should note performance variations across tests and potential cross-reactivity.


Subject(s)
Humans , Antibodies , Dengue Virus , Dengue , Diagnosis , Diagnostic Tests, Routine , Enzyme-Linked Immunosorbent Assay , Immunoglobulin G , Immunoglobulin M
5.
Annals of Laboratory Medicine ; : 578-584, 2018.
Article in English | WPRIM | ID: wpr-718324

ABSTRACT

BACKGROUND: Accurate, rapid, and cost-effective screening tests for hepatitis B virus (HBV) and hepatitis C virus (HCV) infection may be useful in laboratories that cannot afford automated chemiluminescent immunoassays (CLIAs). We evaluated the diagnostic performance of a novel rapid automated fluorescent lateral flow immunoassay (LFIA). METHODS: A fluorescent LFIA using a small bench-top fluorescence reader, Automated Fluorescent Immunoassay System (AFIAS; Boditech Med Inc., Chuncheon, Korea), was developed for qualitative detection of hepatitis B surface antigen (HBsAg), antibody to HBsAg (anti-HBs), and antibody to HCV (anti-HCV) within 20 minutes. We compared the diagnostic performance of AFIAS with that of automated CLIAs—Elecsys (Roche Diagnostics GmbH, Penzberg, Germany) and ARCHITECT (Abbott Laboratories, Abbott Park, IL, USA)—using 20 seroconversion panels and 3,500 clinical serum samples. RESULTS: Evaluation with the seroconversion panels demonstrated that AFIAS had adequate sensitivity for HBsAg and anti-HCV detection. From the clinical samples, AFIAS sensitivity and specificity were 99.8% and 99.3% for the HBsAg test, 100.0% and 100.0% for the anti-HBs test, and 98.8% and 99.1% for the anti-HCV test, respectively. Its agreement rates with the Elecsys HBsAg, anti-HBs, and anti-HCV detection assays were 99.4%, 100.0%, and 99.0%, respectively. AFIAS detected all samples with HBsAg genotypes A-F and H and anti-HCV genotypes 1, 1a, 1b, 2a, 2b, 4, and 6. Cross-reactivity with other infections was not observed. CONCLUSIONS: The AFIAS HBsAg, anti-HBs, and anti-HCV tests demonstrated diagnostic performance equivalent to current automated CLIAs. AFIAS could be used for a large-scale HBV or HCV screening in low-resource laboratories or low-to middle-income areas.


Subject(s)
Fluorescence , Genotype , Hepacivirus , Hepatitis B Surface Antigens , Hepatitis B virus , Hepatitis B , Hepatitis C , Hepatitis , Immunoassay , Mass Screening , Sensitivity and Specificity , Seroconversion
6.
Journal of Laboratory Medicine and Quality Assurance ; : 51-69, 2018.
Article in Korean | WPRIM | ID: wpr-714781

ABSTRACT

As part of the immunoserology program of the Korean Association of External Quality Assessment Service, we organized two trials on the external quality assessment of hepatitis viral markers in 2016 and 2017. The hepatitis viral antigens and antibodies program consisted of 10 test items. We delivered two and three types of pooled sera specimens to 965 and 965 institutions for the first and second trials of external proficiency testing in 2016, respectively. The number of participating laboratories was 915 (94.8%) and 913 (95.0%) in the first and second trials in 2016, respectively. We also delivered three kinds of pooled sera specimens to 936 and 1,015 institutions for the first and second trials of external proficiency testing in 2017, respectively. The number of participating laboratories was 920 (98.3%) and 996 (98.1%) in the first and second trials in 2017, respectively. The most commonly tested items were hepatitis B surface antigen, followed by the antibodies to hepatitis B surface antigen, anti-hepatitis C virus, hepatitis B envelope antigen, antibodies to hepatitis B envelope antigen, anti-hepatitis A virus and antibodies to hepatitis B core antigen. The most frequently used methods for detecting viral markers were the chemiluminescence immunoassay and the electrochemiluminescence immunoassay, but they yielded a few-false positive results due to the matrix effect. The immunochromatographic assay yielded false-negative results for anti-hepatitis A virus due to low sensitivity. Continuous improvement in the quality of viral hepatitis testing through participation in the survey seems necessary.


Subject(s)
Antibodies , Antigens, Viral , Biomarkers , Hepatitis A , Hepatitis B , Hepatitis B Core Antigens , Hepatitis B Surface Antigens , Hepatitis B virus , Hepatitis C , Hepatitis , Immunoassay , Chromatography, Affinity , Korea , Laboratory Proficiency Testing , Luminescence
7.
Annals of Laboratory Medicine ; : 45-52, 2017.
Article in English | WPRIM | ID: wpr-72418

ABSTRACT

BACKGROUND: The interaction between killer immunoglobulin-like receptors (KIRs) and HLA class I regulates natural killer (NK) cell cytotoxicity and function. The impact of NK cell alloreactivity through KIR in liver transplantation remains unelucidated. Since the frequency of HLA-C and KIR genotypes show ethnic differences, we assessed the impact of HLA-C, KIR genotype, or KIR-ligand mismatch on the allograft outcome of Korean liver allografts. METHODS: One hundred eighty-two living donor liver transplant patients were studied. Thirty-five patients (19.2%) had biopsy-confirmed acute rejection (AR), and eighteen (9.9%) had graft failure. The HLA-C compatibility, KIR genotypes, ligand-ligand, and KIR-ligand matching was retrospectively investigated for association with allograft outcomes. RESULTS: Homozygous C1 ligands were predominant in both patients and donors, and frequency of the HLA-C2 allele in Koreans was lower than that in other ethnic groups. Despite the significantly lower frequency of the HLA-C2 genotype in Koreans, donors with at least one HLA-C2 allele showed higher rates of AR than donors with no HLA-C2 alleles (29.2% vs 15.7%, P=0.0423). Although KIR genotypes also showed ethnic differences, KIR genotypes and the number of activating KIR/inhibitory KIR were not associated with the allograft outcome. KIR-ligand mismatch was expected in 31.6% of Korean liver transplants and had no impact on AR or graft survival. CONCLUSIONS: This study could not confirm the clinical impact of KIR genotypes and KIR-ligand mismatch. However, we demonstrated that the presence of HLA-C2 allele in the donor influenced AR of Korean liver allografts.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Alleles , Asian People/genetics , Genotype , Graft Rejection , Graft Survival , HLA-C Antigens/genetics , Homozygote , Killer Cells, Natural/cytology , Ligands , Liver Transplantation , Proportional Hazards Models , Receptors, KIR/chemistry , Republic of Korea , Tissue Donors , Transplantation, Homologous
SELECTION OF CITATIONS
SEARCH DETAIL